Installation examples<< Back to overview

Nozzle-side installation

Features:

The gate insert is screwed into the nozzle side of the mould.

The front of the gate insert is sealed off by the cavity.
Melt flow exits in a vertical direction only, ensuring a clean separation for superior gate point quality.
The extractor claw must be strong enough to ensure reliable de-gating.
Use graduated injection profiles to prevent jetting.

Optionally, provide a dead-end recess to

  • reduce pressure loss
  • minimize shear
  • improve frontal flow

thus minimizing the risk of jetting effects.

Back to overview